E0200
Ribs / rafters
385
mm
R
w
48
dB
Insulation between the supporting structure of covering
82
kg/m2
C
-3
dB
Calculation
≈
0.151
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0201
Ribs / rafters
405
mm
R
w
50
dB
Insulation between the supporting structure of covering
84
kg/m2
C
-3
dB
Calculation
≈
0.142
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0202
Ribs / rafters
425
mm
R
w
50
dB
Insulation between the supporting structure of covering
87
kg/m2
C
-3
dB
Calculation
≈
0.133
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0203
Ribs / rafters
445
mm
R
w
50
dB
Insulation between the supporting structure of covering
89
kg/m2
C
-3
dB
Calculation
≈
0.126
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0204
Ribs / rafters
377
mm
R
w
54
dB
Insulation between the supporting structure of covering
86
kg/m2
C
-3
dB
Calculation
≈
0.172
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0205
Ribs / rafters
397
mm
R
w
54
dB
Insulation between the supporting structure of covering
89
kg/m2
C
-3
dB
Calculation
≈
0.16
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0206
Ribs / rafters
417
mm
R
w
54
dB
Insulation between the supporting structure of covering
91
kg/m2
C
-3
dB
Calculation
≈
0.149
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0207
Ribs / rafters
437
mm
R
w
56
dB
Insulation between the supporting structure of covering
93
kg/m2
C
-3
dB
Calculation
≈
0.14
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0208
Ribs / rafters
457
mm
R
w
56
dB
Insulation between the supporting structure of covering
96
kg/m2
C
-3
dB
Calculation
≈
0.132
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0209
Ribs / rafters
477
mm
R
w
56
dB
Insulation between the supporting structure of covering
98
kg/m2
C
-3
dB
Calculation
≈
0.125
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0210
Ribs / rafters
355
mm
R
w
47
dB
Insulation between the supporting structure
77
kg/m2
C
-3
dB
Calculation
≈
0.143
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0211
Ribs / rafters
375
mm
R
w
47
dB
Insulation between the supporting structure
80
kg/m2
C
-3
dB
Calculation
≈
0.125
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0212
Ribs / rafters
395
mm
R
w
47
dB
Insulation between the supporting structure
82
kg/m2
C
-3
dB
Calculation
≈
0.119
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0213
Ribs / rafters
415
mm
R
w
49
dB
Insulation between the supporting structure
85
kg/m2
C
-3
dB
Calculation
≈
0.106
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0214
Ribs / rafters
435
mm
R
w
49
dB
Insulation between the supporting structure
87
kg/m2
C
-3
dB
Calculation
≈
0.101
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0215
Ribs / rafters
455
mm
R
w
50
dB
Insulation between the supporting structure
91
kg/m2
C
-3
dB
Calculation
≈
0.301
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0216
Ribs / rafters
420
mm
R
w
58
dB
Insulation between the supporting structure of covering
95
kg/m2
C
-3
dB
Calculation
≈
0.14
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0217
Ribs / rafters
460
mm
R
w
58
dB
Insulation between the supporting structure of covering
97
kg/m2
C
-3
dB
Calculation
≈
0.132
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0218
Ribs / rafters
480
mm
R
w
58
dB
Insulation between the supporting structure of covering
100
kg/m2
C
-3
dB
Calculation
≈
0.125
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0219
Ribs / rafters
500
mm
R
w
60
dB
Insulation between the supporting structure of covering
102
kg/m2
C
-3
dB
Calculation
≈
0.118
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF